EU standard basic parameters |
model |
Lefu Mobile Max |
Lefu Mobile |
weight |
53.3kg |
48kg |
size |
566*486*329mm |
capacity |
3686.4Wh ,51.2V,16S |
2560wh,51.2V,16S |
approval standards |
CE,ROHS,UN38.3,MSDS,TDG,etc |
ups |
10 ms |
parallel power |
Up to two parallel, 7.2kW |
function |
Up to two parallel, 4.8kW |
APP Connection |
LAN WIFl,Bluetooth |
Output specifications |
AC output (x5) |
220V~60Hz/50Hz,1*20A3*16A |
rated power |
3.6kw |
2.4kw |
USB-A fast charge(x4) |
Support BC1.2,APPLE, Samsung protocol, Qualcomm Qc2.0/QC3.0Huawei FCp fast charge protocol,AFC fast charge protocol, the maximumpower of each channel 18W |
Anderson interface |
12V/30A |
30V/20A |
TYPE-C fast charge(x2) |
Support PD3.0 and PpS protocol, one-way 100w*1+ one-way 60W*1,voltage adaptive |
DC5521output(x2) |
12V/10A each way, parallel port, the maximum of two outlets at the sametime 120w |
cigarette lighteroutput |
Parallel with DC5521,the maximum output is 120W, 12V/10A |
wireless charging |
15W Max |
Ac input |
AC input voltage |
210V-240V~60Hz/50Hz |
|
AC input power |
3200W max(Includes charginggun input) |
1800W max |
AC maximum charging current |
15.6A(City electric10A max, EVCharger 15.6A max) |
9.6A (City electric9.6A max) |
diesel generator charging |
2300W max |
1800W max |
Ac charging gun (3400W) Fastest filling time |
1.4H(Charge to 90% in 1 hour) |
city electric Fastestfilling time |
2H(Charge to 90% in 1.6 hours) |
1.8H(Charge to 90% in 1.4 hours) |
PV charging parameters |
PV charging input |
12V~150V,PV reverse protection |
12V~75V ,PV reverse protection |
PV charging power |
2400W max |
800W max |
maximum charging current |
25A |
25A |
Fastest filling time |
1.9H |
3.6H |
PV and City electric fastest full time |
1.3H |
1.3H |
Cell specification |
Cell material |
LiFePO4(LiFePO4Square aluminum shell) |
cycle life (0.5c Charge-Discharge) |
6000 cycles 280% capacity retention rate, cell energy density 150Wh/kg |
Energy conversion efficiency(23°C) |
0.9 |
Protection |
BMS protection type |
Temperature protection, over discharge protection, over chargeprotection, short circuit protection, over current protection, differentiapressure alarm protection, charge balance protection; Sleep modeprotection |
System protection type |
PV current limiting/power limiting protection, PV night anti-chargeprotection, mains input over/under voltage protection, batteryover/under voltage protection, load output short circuit protection.radiator over temperature protection, overload protection, PVanti-reverse protection, Ac backfilling protection, battery input ovelcurrent protection, battery input protection, charging short circuit protection |